CEDAR

Measurement of torque driver / torque wrench
œ TORQUE TESTER @DIS-IP series
Yes-no decision conditions etc. can save five channels.
.. A channel is only changed even if bolting conditions change.
It is not necessary to reset up a maximum value and a minimum value one by one like former.

Management of various torque wrench torque drivers


The main features
  Yes-no decision@
  Average calculation

  Data storage is 800 affairs.
  A convenient functional setup of a setup of a measurement start value etc.
  Data output at real time (every about 1/180 seconds).@
  USB terminal data output

 It is a rechargeable battery drive, the installation to the spot is also easy.
 By the auto power OFF, It prevents forgetting to turn off the power.
 One-touch zero adjustment
 An auto clearance (0.1 0.5 1.0 1.5 2.0 2.5 3.0 sec) can be set up.
@@It is very convenient for a continuous check.
 The operation torque of a QL type and pre set  type wrench driver can read measured value correctly in peak down mode (P-D).

Specification DIS-IP05 ‚cIS-‚h‚o5 ‚cIS-‚h‚o50 ‚cIS-‚h‚o200 ‚cIS-‚h‚o500
Measuring range
(at  time of Track)
2.0`500 mN₯m
0.20`50 kgfEcm
0.20`45 lbfEin

0.020`5 N₯m
0.20`50 kgfEcm
0.20`45 lbfEin

0.20`50 N₯m
2.0`500 kgfEcm
2.0`450 lbfEin

2.0`200 N₯m
20`2000 kgfEcm
20`1740 lbfEin

2.0`500 N₯m
20`5000 kgfEcm
20`4500 lbfEin

Accuracy }0.5%     (499 or less digit}3digit)
Display The 4 figures digital display of LCD
The measurement direction CW-CCW (right and left)
Measuring
mode
P-P  Peak Peak load value hold.
T-R  Track Indication of real time torque value.
P-D  Peak down Holding Load Value at the moment to change from upward to downword
C Real-time output Load torque value is outputted every about1/ 180 second .
Decision
function
Setting of torque value A Maximum and a minimum value are in a measuring range, and a setup is possible.
Can confirm the set value by the buzzer sound or LED.
The Maximum, the minimum, and the average value The maximum, the minimum value, and average value of the saved data
Automatic Clearance Automatically clear the displayed value after certain time (0.5 - 3.0 sec,selectable at each 0.5 sec). Setting 0.0 sec for manual Zero clearance
One-touch zero Easy Zero-Adjustment with pressing CLEAR button
Data spec. Data transfer ASCII fomat (Baud rate :19200)
Data memory 800 data
Power supply Ni-Cd chargeable battery 1.2V~5cells @700mAh
Auto power save 10 minutes no use, automatically switch off.
Charging time about 3 hours
Continunous working time 12 hours
Meter outside type dimension 100(W) x105(D) x40 (H)  (It does not contain by the projection thing.)
Weight Meter part    520g
Code length Standard 1m (there are automatic machines no less than 4m as an option.)

Accessories
 (one piece each)

AC/DC adaptor
An inspection report, a proofreading certificate, a traceability system figure

Detection machine size figure

Detection machine outside figure
Form IP05/5 IP50 IP200 IP500 Detector
‚` ƒ³40 ƒ³50 ƒ³60 ƒ³80
‚a 41.2 63 79 99
‚b 5 10 15 15.5
‚c ƒ³60 ƒ³90 ƒ³110 ƒ³140
‚d ƒ³50 ƒ³74 ƒ³90 ƒ³116
‚e(Three division) ƒ³4.2 ƒ³6.3 ƒ³8.3 ƒ³10.5
‚f@(Socket intuition affinity) 6.35‚“‚‘ 9.5‚“‚‘ 12.7‚“‚‘ 19‚“‚‘
weight 189‚‡ 632‚‡ 1.8‚‹‚‡ 3‚‹‚‡